Ion Exchanger-Vocabulary
| Exchange capacity: This is the weight of ions that can be retained per unit volume ( or sometime per unit weight ) of the exchange material concerned Bed volume: volume per hours of liquid to be treated / volume of resin Ion flux: Bed volume * salinity of water Regeneration level: weight of reagent used / volume of ion exchange material Regeneration rate: 100* (grams-equivalents of regenerating reagent)/ (grams-equivalents of the eluted ions) Regeneration efficiency: This is the opposite ratio above Ion leakage: This is the concentration of unwanted ion left in the treated liquid Breakthrough: This is the maximum permissible ion leakage requiring the production cycle to be shut down. Attrition: mechanical wear of the exchanger grains as they are being used.
|