Research Papers by N. Kabay

1 - 9 of 9 results

This study is focused on the application of the ion exchange Á submerged microfiltration hybrid process for boron removal from geothermal water containing high level of boron (8 Á 9 mg B/L). The goal of this study is to determine the optimum parameters such as feed flow rate, resin concentration and
Desalination 241 (2009)

The main objective of this work was to investigate and compare the removals of boron from model solutions (boron as single solute in distilled and deionized water) and seawater using two commercial high rejection SWRO membranes. The impacts of dissolved solids in seawater and pH on boron rejection a
Desalination 223 (2008)

Boron removal from aqueous solution by electrodialysis was studied as a function of solution pH, applied voltage, flow rate and initial boron concentration. TS-l-l0 electrodialysis equipment (Tokuyama) modified with rotameters was employed for experimental studies. It was obtained that the highest b
Desalination 223 (2008)

The advanced separation process for boron removal has been put forward by combining boron sorption on a fine powdered boron selective resin (BSR) with a complex separation on microfiltration membranes. The proposed membrane-based hybrid process integrates in one step sorption efficiency of the selec
Desalination 223 (2008)

The main objective of this work was to investigate boron removal from seawater using two commercial high rejection SWRO membranes. The impact of solution pH, feed concentration, pressure, and cross-flow velocity on boron rejection and permeate flux was determined. The membranes used were the TorayTM
Desalination 227 (2008)

Column-mode removal of boron from geothermal wastewaters of the Kizildere Geothermal Power Station, Denizli, was performed using Diaion CRB 02 N-glucamine-type chelating resins. The resin was tested for 10 sorptionwashing-elution-washing-regeneration-washing cycles in the geothermal field. The boron
Desalination 167 (2004)

The separation performance of K+ ions from KCl solution has been investigated by electrodialysis at constant voltage mode of operation as a function of flow rate and voltage scanned. TS-1-10 model electrodialysis equipment (Tokuyama) modified with rotameters was employed in experimental runs. The ef
Desalination 153 (2002)

The separation performances of divalent ions (Ca2+ and Mg2+) by electrodialysis (ED) were compared using a constant voltage mode of operation. For the batch tests, TS-1-10 ED equipment was employed. During the experimental studies, the effects of electrical potential applied and flow rate of streams
Desalination 149 (2002)

The separation performance of Na+ ions from NaCl solution has been investigated by electrodialysis at constant voltage mode of operation. TS-1-10 electrodialysis equipment (Tokuyama) modified with rotameters was employed in experimental studies. During an unsteady-state run of the ED system, both in
Desalination 136 (2001)