PES
1 - 3 of 3 results
|
This paper investigates a methodology for the characterisation and location of a thin layer of irreversible fouling in a spiral-wound ultrafiltration membrane by using several physico-chemical techniques as SEM-EDX, SEMFEG, FTIR-ATR and AFM. Application to analysis of a spiral-wound PES membrane for
Desalination 192 (2006)
|
|
The objective of this paper is to characterise and locate the thin layer of irreversible fouling in a spiral-wound membrane of ultrafiltration of acid whey, after 8000 h of production in a French dairy. Several physico-chemical techniques as SEM-EDX, SEM-FEG, FTIR-ATR and AFM were used. Fouling was
Desalination 192 (2006)
|
|
The cleaning of an ultrafiltration polyethersulfone (PES) membrane fouled by skimmed milk was studied by ATR–FTIR showing the functional groups of fouling species and EDX coupled with SEM measuring the atomic composition. Two kinds of fouling conditions were studied: further so-called “static condit